[ Identification | Description | Input parameters | Links ]
Test_Sqw_monitor
InstrumentThis instrument models a generic, tunable, neutron time-of-flight spectrometer. The incoming flux at the sample brings neutrons with 'beam_wavelength_Angs' wavelength. The energy resolution at the sample is given as 'beam_resolution_meV'. The beam size at the sample is set to the sample cross section (e.g. ~2 x 5 cm). The sample geometry is either cylindrical ('sample_radius_m' and 'sample_height_m') or spherical ('sample_height_m=0'). The sample can be hollow when given a thickness 'sample_thickness_m', or filled ('sample_thickness_m=0'). When in cylindrical geometry, it is surrounded by a container with thickness 'container_thickness_m'. The container material is specified as a powder file name 'container' in the McStas Sqw or PowderN format, e.g. 'Al.laz' or 'Nb.laz'. Setting 'container=0' removes the container. The sample scattering is characterised by its coherent and incoherent contributions given as 'sample_coh' and 'sample_inc' file names in McStas Sqw or PowderN format. Setting the 'sample_coh=sample_inc=0' removes the sample, e.g. to study the container or environment only contribution. The sample and its container are located inside a cylindrical shield with radius 'environment_radius_m' and thickness 'environment_thickness_m'. The material is set from the 'environment' file name in the McStas Sqw or PowderN format (e.g. 'Al.laz'). This way, it is possible to estimate the contribution of a cryostat or furnace. Setting 'environment=0' removes the environment. The detector has a cylindrical geometry, with a radius 'sample_detector_distance_m' and tubes with height 'detector_height_m'. The detector covers a -30 to 140 deg angular range with 2.54 cm diameter tubes (the number of tubes is computed from the distance). The direct beam (non scattered neutrons) is discarded. The detector produces both (angle,tof) and (q,w) data sets, for: total scattering coherent single scattering from sample incoherent single scattering from sample multiple scattering from sample scattering from the container and sample environment The (angle,tof) results are corrected for the parallax effect from the detector height. Known configurations: ILL_IN4: beam_wavelength_Angs=2, beam_resolution_meV=0.5, sample_detector_distance_m=2.0, detector_height_m=0.3 ILL_IN5: beam_wavelength_Angs=5, beam_resolution_meV=0.1, sample_detector_distance_m=4.0, detector_height_m=3.0 ILL_IN6: beam_wavelength_Angs=4.1, beam_resolution_meV=0.1, sample_detector_distance_m=2.48, detector_height_m=1.2 PSI_Focus: beam_wavelength_Angs=4.1, beam_resolution_meV=0.1, sample_detector_distance_m=2.5, detector_height_m=1.2 FRM2_TOFTOF: beam_wavelength_Angs=3.0, beam_resolution_meV=0.3, sample_detector_distance_m=4.0, detector_height_m=2.0 SNS_SEQUOIA: beam_wavelength_Angs=1.0, beam_resolution_meV=3.0, sample_detector_distance_m=5.5, detector_height_m=1.2 SNS_ARCS: beam_wavelength_Angs=0.3, beam_resolution_meV=20.0, sample_detector_distance_m=3.0, detector_height_m=1.46 NIST_DCS: beam_wavelength_Angs=3.0, beam_resolution_meV=0.2, sample_detector_distance_m=4.0, detector_height_m=1.2 ISIS_MERLIN: beam_wavelength_Angs=1.0, beam_resolution_meV=2.4, sample_detector_distance_m=2.5, detector_height_m=3.0 ISIS_LET: beam_wavelength_Angs=4.0, beam_resolution_meV=0.1, sample_detector_distance_m=3.5, detector_height_m=4.0
Name | Unit | Description | Default |
beam_wavelength_Angs | Angs | incident neutron beam wavelength | 2 |
beam_resolution_meV | meV | incident energy range full width | 0.1 |
sample_coh | str | sample coherent Sqw data file or NULL | "Rb_liq_coh.sqw" |
sample_inc | str | sample incoherent Sqw data file or NULL | "Rb_liq_inc.sqw" |
sample_thickness_m | m | thickness of sample. 0=filled | 1e-3 |
sample_height_m | m | height of sample. 0=sphere | 0.03 |
sample_radius_m | m | radius of sample (outer) | 0.005 |
container | str | container material or NULL | "Al.laz" |
container_thickness_m | m | container thickness | 50e-6 |
environment | str | sample environment material or NULL | "Al.laz" |
environment_radius_m | m | sample environment outer radius | 0.025 |
environment_thickness_m | m | sample environment thickness | 2e-3 |
detector_height_m | m | detector tubes height | 3 |
sample_detector_distance_m | m | distance from sample to detector | 4.0 |
Test_Sqw_monitor.instr
.
[ Identification | Description | Input parameters | Links ]
Generated on 2024-01-03 11:47:43