The SANS_Liposomes_Abs Component

Solid dilute monodisperse spheres sample with transmitted beam for Small Angle Neutron Scattering.

Identification

Description

Sample for Small Angle Neutron Scattering.
Modified from the Any Sample model.
Normalization of scattering is done in INITIALIZE.
Some elements of Sans_spheres have been re-used

Some remarks:
Scattering function should be a defined the same way in INITIALIZE and TRACE sections
There exist maybe better library functions for the integral.

Transmitted paths set to 50% of all paths to be optimised for SESANS. In this simulation method paths are
well distributed among transmission and scattering (equally in Q-space).

Sample components leave the units of flux for the probability
of the individual paths. That is more consitent than the
Sans_spheres routine. Furthermore one can simulate the
transmitted beam. This allows to determine the needed size of
the beam stop. Absorption is included to
these sample-components.

Example: SANS_Spheres_Abs(R=100, Phi=1e-3, Delta_rho=0.6, sigma_a = 50, qmax=0.03, xwidth=0.01, yheight=0.01, zthick=0.001)

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
R100
dR0.0
Phi1e-3
Delta_rho0.6
sigma_aAbsorption cross section density at 2200 m/s (m^-1)0.50
qmax0.03
xwidth0.01
yheight0.01
zthick0.001
dbilayer35