[ Identification | Description | Input parameters | Links ]
SANS_Liposomes_Abs
ComponentSample for Small Angle Neutron Scattering. Modified from the Any Sample model. Normalization of scattering is done in INITIALIZE. Some elements of Sans_spheres have been re-used Some remarks: Scattering function should be a defined the same way in INITIALIZE and TRACE sections There exist maybe better library functions for the integral. Transmitted paths set to 50% of all paths to be optimised for SESANS. In this simulation method paths are well distributed among transmission and scattering (equally in Q-space). Sample components leave the units of flux for the probability of the individual paths. That is more consitent than the Sans_spheres routine. Furthermore one can simulate the transmitted beam. This allows to determine the needed size of the beam stop. Absorption is included to these sample-components. Example: SANS_Spheres_Abs(R=100, Phi=1e-3, Delta_rho=0.6, sigma_a = 50, qmax=0.03, xwidth=0.01, yheight=0.01, zthick=0.001)
Name | Unit | Description | Default | |
R | 100 | |||
dR | 0.0 | |||
Phi | 1e-3 | |||
Delta_rho | 0.6 | |||
sigma_a | Absorption cross section density at 2200 m/s (m^-1) | 0.50 | ||
qmax | 0.03 | |||
xwidth | 0.01 | |||
yheight | 0.01 | |||
zthick | 0.001 | |||
dbilayer | 35 |
AT ( | , | , | ) RELATIVE | |||
---|---|---|---|---|---|---|
ROTATED ( | , | , | ) RELATIVE |
SANS_Liposomes_Abs.comp
.
[ Identification | Description | Input parameters | Links ]
Generated on mcstas 3.5.24