14.107 The TOF2Q_cyl_monitor McStas Component
Release: McStas 2.0
Cylindrical (2pi) 2theta v. q Time-of-flight monitor.
Identification
-
Author: Kim Lefmann
-
Origin: Risoe
-
Date: October 2000
Description
Cylindrical (2pi) 2theta v. q Time-of-flight monitor.
Input parameters
Parameters in boldface are required; the others are optional.
|
|
|
Name |
Unit |
Description |
Default |
|
|
|
|
| | | | |
|
nq |
1 |
Number of q bins |
100 |
|
nphi |
1 |
Number of angular bins |
100 |
|
nh |
1 |
Number of bins in detector height |
10 |
|
restore_neutron |
1 |
If set, the monitor does not influence the
neutron state |
0 |
|
filename |
str |
Name of file in which to store the
detector image |
0 |
|
radius |
m |
Cylinder radius |
1.0 |
|
height |
m |
Cylinder height |
0.1 |
|
q_min |
1/Å |
Minimum q value |
0 |
|
q_max |
1/Å |
Maximum q value |
20 |
|
L_chop2samp |
m |
Distance from resolution chopper to
sample position |
144.0 |
|
t_chop |
ms |
Flight time of mean wave length from
source to resolution chopper |
0.004 |
|
pixel |
1 |
Flag, 0: no pixelation and perfect time. 1:
make pixels from nphi and nh and time
resolution limitation. |
1 |
|
|
| |
| |
|
|
|
|
|
|
Links